PrimePCR™ SYBR® Green Assay: GRIA4, Human

PrimePCR Primer Assays for Real-Time PCR oligo primer pair tube for SYBR Green gene expression

Real-time PCR primer assay designed for SYBR® Green gene expression analysis.

Info:   Recommended - best coverage; Same primer pair as used in probe assay qHsaCEP0052833

List Price:    $174.00
Your Price:   Log In
 
Add to Custom Plate

Assay Information

Technology:   qPCR
Assay Type:   SYBR® Green
Application:   Gene Expression
Unique Assay ID:   qHsaCED0045572
Assay Design:   exonic
Chromosome Location:   11:105483004-105483132question
Amplicon Length:   99
Splice Variants Targeted:   ENST00000527177 ENST00000393125 ENST00000531986 ENST00000527669 ENST00000525921 ENST00000428631 ENST00000531011 ENST00000525187 ENST00000530497 ENST00000282499 ENST00000393127

Gene Information

Glutamate receptors are the predominant excitatory neurotransmitter receptors in the mammalian brain and are activated in a variety of normal neurophysiologic processes. These receptors are heteromeric protein complexes composed of multiple subunits arranged to form ligand-gated ion channels. The classification of glutamate receptors is based on their activation by different pharmacologic agonists. The subunit encoded by this gene belongs to a family of AMPA (alpha-amino-3-hydroxy-5-methyl-4-isoxazole propionate)-sensitive glutamate receptors and is subject to RNA editing (AGA->GGA; R->G). Alternative splicing of this gene results in transcript variants encoding different isoforms which may vary in their signal transduction properties. Some haplotypes of this gene show a positive association with schizophrenia. [provided by RefSeq Jul 2008]

Gene Symbol:   GRIA4
Gene Name:   glutamate receptor, ionotrophic, AMPA 4
Aliases:   GLUR4, GLUR4C, GLURD, GluA4
RefSeq:   NC_000011.9 NT_033899.8
Ensembl:   ENSG00000152578
Entrez:   2893
Chromosome Mapping:   11q22

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999300
y-intercept 35.670000
Efficiency 97

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download