PrimePCR™ Probe Assay: CLCN1, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $263.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCEP0058176
Assay Design:   exonic
Chromosome Location:   7:143016849-143017768question
Amplicon Length:   102
Splice Variants Targeted:   ENST00000343257

Gene Information

The CLCN family of voltage-dependent chloride channel genes comprises nine members (CLCN1-7 Ka and Kb) which demonstrate quite diverse functional characteristics while sharing significant sequence homology. The protein encoded by this gene regulates the electric excitability of the skeletal muscle membrane. Mutations in this gene cause two forms of inherited human muscle disorders: recessive generalized myotonia congenita (Becker) and dominant myotonia (Thomsen). Alternative splicing results in multiple transcript variants. [provided by RefSeq Mar 2012]

Gene Symbol:   CLCN1
Gene Name:   chloride channel 1, skeletal muscle
Aliases:   CLC1, MGC138361, MGC142055
RefSeq:   NC_000007.13 NG_009815.1 NT_007914.15
Ensembl:   ENSG00000188037
Entrez:   1180
Chromosome Mapping:   7q32-qter,7q35

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999300
y-intercept 35.680000
Efficiency 99

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download