Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   lncRNA Expression
Unique Assay ID:   qhsaLEP0141831
Assay Design:   exonic
Chromosome Location:   chr21:17448924-17449069question
Amplicon Length:   116
Refseq Transcripts Amplified:   NR_037585,NR_037586
Splice Variants Targeted:   ENST00000440664
LNCipedia Splice Variants Targeted:   LINC01549:3 LINC01549:1 LINC01549:2

Gene Information

Description Not Available

Gene Symbol:   C21orf37
Gene Name:   chromosome 21 open reading frame 37
Aliases:   Not Available
RefSeq:   NC_000021.8 NT_011512.11
Ensembl:   ENSG00000232560
LNCipedia:   LINC01549
Entrez:   100505929
Chromosome Mapping:   21q21.1
Gene Strand:   Not Available

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999700
y-intercept 37.049999
Efficiency 1.98

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download