PrimePCR™ Probe Assay: PLA2G5, Human

RT

Real-time PCR probe assay designed for gene expression analysis. Probe assays consist of unlabeled PCR primers and a dual labeled fluorescent probe.

List Price:    $255.00
Your Price:   Log In
 

Assay Information

Technology:   qPCR
Assay Type:   Probe
Application:   Gene Expression
Unique Assay ID:   qHsaCEP0051447
Assay Design:   exonic
Chromosome Location:   1:20417250-20417395question
Amplicon Length:   116
Splice Variants Targeted:   ENST00000375108

Gene Information

This gene is a member of the secretory phospholipase A2 family. It is located in a tightly-linked cluster of secretory phospholipase A2 genes on chromosome 1. The encoded enzyme catalyzes the hydrolysis of membrane phospholipids to generate lysophospholipids and free fatty acids including arachidonic acid. It preferentially hydrolyzes linoleoyl-containing phosphatidylcholine substrates. Secretion of this enzyme is thought to induce inflammatory responses in neighboring cells. Alternatively spliced transcript variants have been found but their full-length nature has not been determined. [provided by RefSeq Jul 2008]

Gene Symbol:   PLA2G5
Gene Name:   phospholipase A2, group V
Aliases:   DKFZp686C2294, GV-PLA2, MGC46205, PLA2-10, hVPLA(2)
RefSeq:   NC_000001.10 NT_004610.19
Ensembl:   ENSG00000127472
Entrez:   5322
Chromosome Mapping:   1p36-p34

The below validation information is for the Primer Pair only   Download Validation Data (.pdf)


Products used to generate validation data:

Real-Time PCR Instrument CFX384 Real-Time PCR Detection System
Reverse Transcription Reagent iScript™ Advanced cDNA Synthesis Kit for RT-qPCR
Real-Time PCR Supermix SsoAdvanced™ Universal SYBR® Green Supermix
Experimental Sample qPCR Human Reference Total RNA

Summary Data:

R2 0.999800
y-intercept 36.230000
Efficiency 96

Amplification Plot
Amplification of cDNA generated from universal RNA.

Amplification of cDNA generated from universal RNA.

Melt Peak
Melt curve analysis of above amplification.

Melt curve analysis of above amplification.

Standard Curve
Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Standard curve generated using 20 million copies of template diluted 10 fold to 20 copies.

Number Description Download
10039761 PrimePCR™ Assays Quick Guide, Ver B Click to download
10042030 PrimePCR™ PreAmp Assay Quick Guide, Rev A Click to download
10000088666 Instruction Manual, PrimePCR Assays, Panels, and Controls, Ver G Click to download
10000143205 SARS-CoV-2 Variant Detection RT-PCR Assay Protocol Click to download
3226 PIS_PrimePCR SARS-CoV-2 Single and Multiple Mutation Assays Click to download
10000147102 PrimePCR SARS-CoV-2 Multiple Mutation Assay Protocol Click to download